476 | -- | 477 | Gareth Jones. Guest Editorial |
479 | -- | 482 | Branislav Djokic, Eddy So. Calibration system for electronic instrument transformers with digital output |
483 | -- | 487 | Ilya Budovsky, Greg M. Hammond. Precision measurement of power harmonics and flicker |
488 | -- | 491 | Paul Clarkson, Paul S. Wright. A wavelet-based method of measuring fluctuating harmonics for determining the filter time constant of IEC standard harmonic analyzers |
492 | -- | 495 | Paul S. Wright. Accurate analysis of smoothly modulated AC waveforms applied to the calibration of fluctuating harmonic analyzers |
496 | -- | 499 | Gregory A. Kyriazis, Marcello L. R. de Campos. An algorithm for accurately estimating the harmonic magnitudes and phase shifts of periodic signals with asynchronous sampling |
500 | -- | 502 | Daniel Slomovitz, Heriguatí de Souza. Shielded electronic current transformer |
503 | -- | 506 | Réjean Arseneau, Eddy So, Ernst Hanique. Measurements and correction of no-load losses of power transformers |
507 | -- | 511 | Eddy So, D. Angelo, Takuhiro Tsuchiyama, Takuya Tadokoro, Bryan C. Waltrip, Tom L. Nelson. Intercomparison of calibration systems for AC shunts up to audio frequencies |
512 | -- | 515 | Jürgen Schurr, Barry M. Wood, Frédéric Overney. Linear frequency dependence in AC resistance measurement |
516 | -- | 520 | Shakil A. Awan, Bryan P. Kibble. Towards accurate measurement of the frequency dependence of capacitance and resistance standards up to 10 MHz |
521 | -- | 524 | Günther Ramm, Harald Moser. New multifrequency method for the determination of the dissipation factor of capacitors and of the time constant of resistors |
525 | -- | 528 | Randolph E. Elmquist, Emmanouel Hourdakis, Dean G. Jarrett, Neil M. Zimmerman. Direct resistance comparisons from the QHR to100 MΩ using a cryogenic current comparator |
529 | -- | 532 | Luca Callegaro. On strategies for automatic bridge balancing |
538 | -- | 541 | Rae Duk Lee, Han Jun Kim, Yu. P. Semenov. Quasi-monolithic toroidal cross-capacitor |
542 | -- | 545 | Yicheng Wang, Scott H. Shields. Improved capacitance measurements with respect to a 1-pF cross-capacitor from 200 to 2000 Hz |
546 | -- | 549 | Han Jun Kim, Rae Duk Lee, Yu. P. Semenov. Compact inductance standard |
550 | -- | 553 | Thomas J. Witt. Allan variances and spectral densities for DC voltage measurements with polarity reversals |
554 | -- | 558 | Helko E. van den Brom, Pieter de la Court, Gert Rietveld. Accurate subpicoampere current source based on a differentiating capacitor with software-controlled nonlinearity compensation |
559 | -- | 562 | Oliver Power, James E. Walsh. In-service characterization of electronic voltage standards |
563 | -- | 566 | Anu Kärkkäinen, Shakil A. Awan, Jukka Kyynäräinen, Panu Pekko, Aarne S. Oja, Heikki Seppä. Optimized design and process for making a DC voltage reference based on MEMS |
567 | -- | 570 | Thomas J. Witt, Yi-Hua Tang. Investigations of noise in measurements of electronic voltage standards |
571 | -- | 575 | Ling Xiang Liu, Sze Wey Chua, Chee Kiang Ang. Determination of DC voltage ratio of a self-calibrating DC voltage divider |
576 | -- | 579 | Giancarlo Marullo-Reedtz, Roberto Cerri, Wolfgang Waldmann, Jiri Streit, Pekka Immonen, Isabelle Blanc, Felix Raso, Torsten Funck, Bernd Schumacher, Erik F. Dierikx, Mario Nunes, Peter Vrabcek, Dusan Rudohradsky, Ove Gunnarsson, Karl-Erik Rydler, Blaise Jeanneret, Beat Jeckelmann, Thomas Pulfer, Saliha Selcik Turhan, Okan Yilmaz, Jonathan M. Williams, Harald Slinde, Kare Lind, Jacques Nicolas, Matjaz Lindic, Eirini Flouda, Gábor Erdös. Comparison EUROMET.EM-K8 of DC voltage ratio: results |
580 | -- | 583 | Eddy So, Branislav Djokic. A hybrid electronically coupled current comparator |
584 | -- | 587 | Ling Hao, John C. Macfarlane, Simon Haining, John C. Gallop. HTS superconducting current comparator: dynamic range and noise limits |
588 | -- | 591 | Giorgio Boella, Iulian Mihai, Giancarlo Marullo-Reedtz, Pier Paolo Capra, Enrico Gasparotto. The IEN CCC bridge to scale the quantized Hall resistance to 1-Ω standards |
592 | -- | 594 | Shiyan Ren, Huayun Yang, Xiaowei Wang. The theoretical analysis of open-loop characteristic for double magnetic detector comparator |
595 | -- | 599 | Anu Kärkkäinen, Nadine Pesonen, Mika Suhonen, Aarne S. Oja, Antti Manninen, Nikolai Tisnek, Heikki Seppä. MEMS-based AC voltage reference |
600 | -- | 603 | Greig W. Small, Ilya F. Budovsky, A. Michael Gibbes, John R. Fiander. Precision three-stage 1000 V/50 Hz inductive voltage divider |
604 | -- | 607 | Branislav Djokic, Eddy So. The development of a digital sampling system for low power factor measurements of high-voltage capacitive/inductive reactors |
608 | -- | 611 | Yi Li, Jari K. Hällström, Wolfgang Lucas. Comparison of two impulse calibrators with a high-resolution digitizer |
612 | -- | 615 | Ralf Behr, Jonathan M. Williams, Pravin Patel, Theodoor J. B. M. Janssen, Torsten Funck, Manfred Klonz. Synthesis of precision waveforms using a SINIS Josephson junction array |
616 | -- | 619 | Yonuk Chong, Charles J. Burroughs, Paul D. Dresselhaus, Nicolas Hadacek, Hirotake Yamamori, Samuel P. Benz. 2.6-V high-resolution programmable Josephson voltage standard circuits using double-stacked MoSi::2::-barrier junctions |
620 | -- | 623 | Mayumi Ishizaki, Hirotake Yamamori, Akira Shoji, Paul D. Dresselhaus, Samuel P. Benz. Programmable Josephson voltage standard circuits using arrays of NbN/TiN/NbN/TiN/NbN double-junction stacks operated at 10 K |
624 | -- | 627 | Charles J. Burroughs, Samuel P. Benz, Paul D. Dresselhaus, Yonuk Chong. Precision measurements of AC Josephson voltage standard operating margins |
628 | -- | 631 | Oleg A. Chevtchenko, Helko E. van den Brom, Ernest Houtzager, Ralf Behr, Johannes Kohlmann, Jonathan M. Williams, Theodoor J. B. M. Janssen, Luis Palafox, David A. Humphreys, François P. M. Piquemal, Sophie Djordjevic, O. Monnoye, André Poletaeff, Rado Lapuh, Karl-Erik Rydler, Gunnar Eklund. Realization of a quantum standard for AC voltage: overview of a European research project |
632 | -- | 635 | Juha Hassel, Panu Helistö, Leif Grönberg, Heikki Seppä, Jaani Nissilä, Antti Kemppinen. Stimulated power generation in ES-SIS junction arrays |
636 | -- | 640 | Jaani Nissilä, Antti Kemppinen, Kari Ojasalo, Juha Hassel, Antti Manninen, Panu Helistö, Heikki Seppä. Realization of a square-wave voltage with externally-shunted SIS Josephson junction arrays for a quantum AC voltage standard |
641 | -- | 644 | Kyu-Tae Kim, Mun-Seog Kim, Myungsoo Kim, Jürgen Niemeyer. Josephson voltage standard as a current reference and practical method for stabilization of high current |
645 | -- | 648 | Chiharu Urano, Yasushi Murayama, Akio Iwasa, Akira Shoji, Hirotake Yamamori, Mayumi Ishizaki. A precise evaluation of NbN-based 1-V programmable Josephson voltage standard arrays |
649 | -- | 652 | Waldemar G. Kürten, Enrico Mohns, Ralf Behr, Jonathan M. Williams, Pravin Patel, Günther Ramm, Hans Bachmair. Characterization of a high-resolution analog-to-digital converter with a Josephson AC voltage source |
653 | -- | 657 | Sae Woo Nam, Samuel P. Benz, Paul D. Dresselhaus, Charles J. Burroughs, Wes Tew, Rod White, John M. Martinis. Progress on Johnson noise thermometry using a quantum voltage noise source for calibration |
658 | -- | 661 | Frédéric Overney, Blaise Jeanneret, Barry M. Wood, Jürgen Schurr. Influence of the dissipation in AC measurements of the quantized Hall resistance |
662 | -- | 665 | Brian W. Ricketts, John R. Fiander, H. Leigh Johnson. Effects of guard surfaces on AC quantized Hall resistance steps |
666 | -- | 669 | Hansjörg Scherer, Sergey V. Lotkhov, Gerd-Dietmar Willenberg, Alexander B. Zorin. Steps toward a capacitance standard based on single-electron counting at PTB |
670 | -- | 672 | Christian Hof, Blaise Jeanneret, Ali L. Eichenberger, Frédéric Overney, Mark W. Keller, M. J. Dalberth. Manipulating single electrons with a seven-junction pump |
676 | -- | 679 | Ulrich Stumper. Uncertainty of VNA S-parameter measurement due to nonideal TRL calibration items |
680 | -- | 683 | David A. Humphreys, James Miall. Traceable RF peak power measurements for mobile communications |
684 | -- | 687 | Luciano Brunetti, Emil T. Vremera. New calibration method for coaxial microcalorimeters |
688 | -- | 691 | Michiyuki Endo, Takeumi Inoue. A double calorimeter for 10-W level laser power measurements |
692 | -- | 695 | David C. Paulusse, Nelson L. Rowell, Alain Michaud. Accuracy of an atomic microwave power standard |
696 | -- | 700 | Wojciech Wiatr, David K. Walker. Systematic errors of noise parameter determination caused by imperfect source impedance measurement |
701 | -- | 704 | Jin-Seob Kang, Jeong Hwan Kim, Dae-Chan Kim. Phase analysis of coaxial short and open circuits |
705 | -- | 708 | Joo-Gwang Lee, Jeong Hwan Kim, Jeong-Il Park, Ung-Taeg Kang. Uncertainty evaluation of a broadband attenuation standard |
709 | -- | 712 | Thomas Musch, Michael Gerding, Burkhard Schiek. A phase-locked-loop concept for the generation of two RF-signals with a small frequency offset |
713 | -- | 717 | Kurt Weyand. Compensation of the temperature coefficient of magnetic field coils |
718 | -- | 721 | Gabriella Crotti, Domenico Giordano. Evaluation of frequency behavior of coils for reference magnetic field generation |
722 | -- | 726 | Oriano Bottauscio, Mario Chiampi, Gabriella Crotti, Mauro Zucca. Probe influence on the measurement accuracy of nonuniform LF magnetic fields |
727 | -- | 729 | Vladlen Ya. Shifrin, Vyacheslav N. Khorev, A. E. Shilov, Po Gyu Park. A standard quantum measuring system for reproduction and measurement of low direct magnetic field in the range 0.1 μT-1.5 mT |
730 | -- | 733 | He Qing, Li Zhengkun. A novel apparatus for measuring permeability of weak magnetic materials |
734 | -- | 737 | Po Gyu Park, Young-Gyun Kim, V. Ya. Shifrin. Maintenance of magnetic flux density standards on the basis of proton gyromagnetic ratio at KRISS |
742 | -- | 745 | Pierre Gournay, Gérard Genevès, Francisco Alves, Mondher Besbes, François Villar, J. David. Magnetic circuit design for the BNM Watt balance experiment |
746 | -- | 749 | Long Sheng Ma, Zhiyi Bi, Albrecht Bartels, Lennart Robertsson, Massimo Zucco, Robert Windeler, Guido Wilpers, Chris Oates, Leo Hollberg, Scott A. Diddams. International comparisons of femtosecond laser frequency combs |
750 | -- | 753 | Harald Schnatz, Burghard Lipphardt, Carsten Degenhardt, Ekkehard Peik, Tobias Schneider, Uwe Sterr, Christian Tamm. Optical frequency measurements using fs-comb generators |
754 | -- | 758 | Frédéric du Burck, Christophe Daussy, Anne Amy-Klein, Andrei N. Goncharov, Olivier Lopez, Christian Chardonnet, Jean-Pierre Wallerand. Frequency measurement of an Ar:::+::: laser stabilized on narrow lines of molecular iodine at 501.7 nm |
759 | -- | 762 | Kazumoto Hosaka, Stephen A. Webster, Peter J. Blythe, Adrian Stannard, David Beaton, Helen S. Margolis, Stephen N. Lea, Patrick Gill. An optical frequency standard based on the electric octupole transition in :::171:::Yb:::+::: |
763 | -- | 766 | Hajime Inaba, Shinya Yanagimachi, Feng-Lei Hong, Atsushi Onae, Yasuki Koga, Hirokazu Matsumoto. Stability degradation factors evaluated by phase noise measurement in an optical-microwave frequency link using an optical frequency comb |
767 | -- | 770 | Hyeyoung Ahn, Ren-Huei Shu, Robert Windeler, Jin-Long Peng. Building a frequency-stabilized mode-locked femtosecond laser for optical frequency metrology |
771 | -- | 775 | Carsten Degenhardt, Tatiana Nazarova, Christian Lisdat, Hardo Stoehr, Uwe Sterr, Fritz Riehle. Influence of chirped excitation pulses in an optical clock with ultracold calcium atoms |
776 | -- | 779 | Thomas Zanon, Stéphane Tremine, Stéphane Guérandel, Emeric de Clercq, David Holleville, Noël Dimarcq, André Clairon. Observation of Raman-Ramsey fringes with optical CPT pulses |
780 | -- | 782 | Young-Ho Park, Cha-Hwan Oh, Pill-Soo Kim, Taeg Yong Kwon, Sang-Eon Park, Sang-Kyung Choi, Ho Seong Lee. Cavity pulling shift evaluated from AC Zeeman shift in an optically-pumped cs beam standard |
783 | -- | 786 | Jes Henningsen, Jan C. Petersen. Molecular transitions as medium-precision wavelength standards for optical communication |
787 | -- | 790 | Manfred Klonz, Günter Schliestedt, Torsten Funck, Milos Stojanovic, Borislav Stojanovic. Millivolt calibrations using micropotentiometers with new disc resistors and planar MJTCS aided by new Millivolt amplifiers |
791 | -- | 794 | Enrico Mohns, Waldemar G. Kürten Ihlenfeld. Fast synchronous AC-DC-transfer with thermal converters |
795 | -- | 798 | Ilya Budovsky, Abdul Rashid Bin Zainal Abidin, Aaron Y. K. Yan, LingXiang Liu, Vijay Kumar Rustagi, Anil Kumar Govil, Manfred Klonz, Yih-cheng Wei, Murray D. Early, Hitoshi Sasaki, Hiroyuki Fujiki, Chalit Kumtawee, Ajchara Charoensook, Sung-Won Kwon, Nguyen Ahn Son, Bambang Suprianto, Moses Temba, Manuel Ruiz, Sabino Paulo B. Leones Jr.. APMP international comparison of AC-DC transfer standards at the lowest attainable level of uncertainty |
799 | -- | 802 | Luciana Scarioni, Manfred Klonz, Torsten Funck. Quartz planar multijunction thermal converter as a new AC-DC current transfer standard up to 1 MHz |
803 | -- | 806 | Héctor Laiz, Thomas F. Wunsch, Joseph R. Kinard, Thomas E. Lipe. 1-A and-120 mA thin-film multijunction thermal converters |
807 | -- | 809 | Torsten Funck, Marian Kampik, Ernst Kessler, Manfred Klonz, Héctor Laiz, Rado Lapuh. Determination of the AC-DC voltage transfer difference of high-voltage transfer standards at low frequencies |
810 | -- | 813 | Umberto Pogliano, Gian Carlo Bosco. Investigations on the electrometric AC-DC transfer standard |
814 | -- | 818 | Philippe Merck, Joseph Achkar. Design of a ku band delay difference calibration device for TWSTFT station |
819 | -- | 824 | Chia-Lung Cheng, Fan-Ren Chang, Kun-Yuan Tu. Highly accurate real-time GPS carrier phase-disciplined oscillator |
825 | -- | 828 | Hsin-Min Peng, Chia-Shu Liao, Jeng-Kuang Hwang. Performance testing of time comparison using GPS-smoothed P3 code and IGS ephemerides |
829 | -- | 832 | Fumimaru Nakagawa, Michito Imae, Yuko Hanado, Masanori Aida. Development of multichannel dual-mixer time difference system to generate UTC (NICT) |
833 | -- | 836 | C. Vian, P. Rosenbusch, H. Marion, Sebastien Bize, L. Cacciapuoti, S. Zhang, M. Abgrall, D. Chambon, I. Maksimovic, P. Laurent, Giorgio Santarelli, André Clairon, A. Luiten, M. Tobar, Christophe Salomon. BNM-SYRTE fountains: recent results |
837 | -- | 841 | W. Chalupczak, Krzysztof Szymaniec, D. Henderson. Cooling in an optical lattice for a caesium fountain frequency standard |
842 | -- | 845 | Thomas P. Heavner, Steven R. Jefferts, Elizabeth A. Donley, Jon H. Shirley, Thomas E. Parker. Recent improvements in NIST-F1 and a resulting accuracy of δf/f=0.61×10:::-15::: |
846 | -- | 849 | Richard Steiner, David B. Newell, Edwin R. Williams, Ruimin Liu, Pierre Gournay. The NIST project for the electronic realization of the kilogram |
850 | -- | 853 | Gérard Genevès, Pierre Gournay, A. Gosset, M. Lecollinet, François Villar, Patrick Pinot, Patrick Juncar, André Clairon, Arnaud Landragin, David Holleville, Franck Pereira Dos Santos, J. David, Mondher Besbes, Francisco Alves, Luc Chassagne, Suat Topçu. The BNM Watt balance project |
854 | -- | 859 | Kenichi Fujii, Atsushi Waseda, Naoki Kuramoto, Shigeki Mizushima, Peter Becker, Horst Bettin, R. Arnold Nicolaus, Ulrich Kuetgens, Staf Valkiers, Philip Taylor, Paul De Bievre, Giovanni Mana, Enrico Massa, Richard Matyi, Ernest Kessler, Michael Hanke. Present State of the avogadro constant determination from silicon Crystals with natural isotopic compositions |
860 | -- | 863 | Christian Schlegel, Dirk Ratschko, Frank Scholz, Michael Gläser. Using an intense bismuth ion beam for the accumulation of a weighable mass of atoms |
864 | -- | 867 | Makoto Yasuhara, Takatoshi Aoki, Hirotaka Narui, Atsuo Morinaga. Measurement of Berry s phase for partial cycles using a time-domain atomic Interferometer |
868 | -- | 871 | Naoki Kuramoto, Kenichi Fujii. Volume determination of a silicon sphere using an improved interferometer with optical frequency tuning |
872 | -- | 876 | R. Arnold Nicolaus, Clemens Elster. Diameter determination of Avogadro Spheres #1 and #2 |
877 | -- | 881 | Horst Bettin, Hans Toth, Atsushi Waseda, Kenichi Fujii. Comparison of density difference measurements at PTB and NMIJ |
882 | -- | 885 | Atsushi Waseda, Kenichi Fujii, Naoyuki Taketoshi. Density measurement of a thin-film by the pressure-of-flotation method |
886 | -- | 889 | Ling Hao, John C. Gallop, John C. Macfarlane. Coupled microwave resonators for sensitive bolometric detection |
890 | -- | 893 | Stefania Castelletto, Ivo Pietro Degiovanni, Giampiero Furno, Valentina Schettini, Alan Migdall, Michael Ware. Two-photon mode preparation and matching efficiency: definition, measurement, and optimization |
894 | -- | 897 | David A. Humphreys, Matthew R. Harper, Andrew J. A. Smith, Ian M. Smith. Vector calibration of optical reference receivers using a frequency-domain method |
898 | -- | 900 | Giorgio Brida, Maria Chekhova, Marco Genovese, Marco Gramegna, Leonid Krivitsky, Maria Luisa Rastello. Absolute quantum efficiency measurements by means of conditioned polarization rotation |