Abstract is missing.
- Improving Step Performance of PMU Algorithms: Left and Right Taylor-Fourier ExpansionsGuglielmo Frigo, Giacomo Gallus, Paolo Attilio Pegoraro, Sergio Toscani. 1-6 [doi]
- Cloud-Based PMUs for Real-Time Power System Monitoring: Theoretical and Experimental AnalysisChemseddine Allioua, Alessandro Mingotti, Roberto Tinarelli, Lorenzo Peretto, Guglielmo Frigo. 1-6 [doi]
- Open-Source Platform for Integrating High-Reporting rate Information Using FIWARE TechnologyRadu Plamanescu, Manuel Pitz, Marwa Maghnie, Catalin Deaconescu, Grigore Stamatescu, Dirk Müller 0005, Antonello Monti, Mihaela M. Albu. 1-6 [doi]
- Reproducibility of Network Impedance Measurements Using Single-Frequency and Broadband Signal InjectionFredrick M. Mwaniki, Morteza Pourarab, Robert Stiegler, Jan Meyer, Dominique Roggo, Blaise Evequoz. 1-6 [doi]
- Linear Distribution System State Estimation by Hybrid Synchronized/Unsynchronized MeasurementsAmin Nassaj, Amir Abiri Jahromi, Kang Li, Vladimir V. Terzija, Sadegh Azizi. 1-6 [doi]
- Optimal Meter Placement for Distribution System State Estimation: A Global Sensitivity Analysis-Based FrameworkMirko Ginocchi, David Pacheco, Marco Pau, Ferdinanda Ponci, Antonello Monti. 1-6 [doi]
- Performance Analysis Based on Real-Field Data of a Method for Locating the Source of Voltage DipsPaolo Castello, Carlo Muscas, Davide Sitzia, Sara Sulis, Johan Rens. 1-5 [doi]
- Optimized 5G Communication Infrastructure for PMU-Based Distributed Measurement SystemsAlberto Morato, Guglielmo Frigo, Federico Tramarin. 1-6 [doi]
- Retrofitting Legacy Substation Monitoring Infrastructure to an Advanced Distribution Management System Employing Middleware: A Case StudyStefano Rinaldi, Marco Pasetti, Federico Broglio, Davide Della Giustina, Alessio Dede. 1-6 [doi]
- Setup for Testing Energy Meters with Disturbed DC Signals Occuring in DC Charging StationsMichael Blaz, Jannes Langemann, Matthias Schmidt, Christoph Leicht. 1-6 [doi]
- Power Quality Assessment with Commercial Microcontroller Devices. Repeatability Measurements of On-Board Harmonic AnalysisGiovanni Artale, Antonio Cataliotti, Lionel Cimaz, Valentina Cosentino, Dario Di Cara, Vito Ditta, Nunzio Dipaola, Salvatore Guaiana, Nicola Panzavecchia, Marilena Sambataro, Giovanni Tinè. 1-6 [doi]
- Implementation of Adaptive Taylor-Fourier Filters on a Real-Time Industrial Controller: Feasibility and Latency AnalysisMarco Agustoni, Guglielmo Frigo. 1-6 [doi]
- Characterization of Voltage Transformers for MV Applications Up to 150 kHz - A Preliminary StudyGabriella Crotti, Giovanni D'Avanzo, Antonio Delle Femine, Daniele Gallo, Domenico Giordano, Claudio Iodice, Carmine Landi, Palma Sara Letizia, Mario Luiso, Paolo Mazza. 1-5 [doi]
- Leveraging Anomaly Detection and AutoML for Modelling Residential Measurement Power TracesGrigore Stamatescu, Radu Plamanescu, Mihaela M. Albu. 1-5 [doi]
- A Novel Method for Accurate Estimation of the Point-On-Wave of Inception and Recovery of Voltage DipsJulio Barros, Matilde de Apráiz, Ramón I. Diego. 1-5 [doi]
- Continuous and Non-Intrusive Energy Monitoring Challenge: Smart Choices in Difficult SituationsOlivia Florencias-Oliveros, Juan José González de la Rosa. 1-6 [doi]
- Synthetic-to-Real Dataset Transfer Learning for Non-Intrusive Load MonitoringPengfei Hao, Liang Zhu, Zhongzong Yan, Yingqi Huang, Yiwei Lei, He Wen. 1-6 [doi]
- Steady-State Phasor Measurement by Means of a Linearized Multiharmonic Sine-Fit AlgorithmDaniel Belega, Dario Petri. 1-6 [doi]
- Fault Identification in Three-Phase Distribution Networks Improved by Line Parameter EstimationPaolo Attilio Pegoraro, Sara Sulis, Carlo Sitzia, Daniele Carta, Antonio Vincenzo Solinas, Andrea Benigni. 1-6 [doi]
- How Undesired Non-Idealities of the Input Signal Affect the Accuracy Evaluation of Instrument Transformers at Power FrequencyGabriella Crotti, Domenico Giordano, Palma Sara Letizia, Davide Signorino, Claudio Iodice, Mario Luiso, Paolo Mazza, Daniele Palladini. 1-6 [doi]
- Setup for the Calibration of Current Measuring Systems Under DC Signals Affected by RippleDomenico Giordano, Davide Signorino, Antonio Delle Femine, Daniele Gallo. 1-6 [doi]
- Simplified Test Method for Harmonic Characterization of Rogowski Coils Under Varying TemperaturesChristian Betti, Alessandro Mingotti, Roberto Tinarelli, Lorenzo Peretto. 1-5 [doi]
- Novel Algorithms for Filtering and Event Detection in Non-Intrusive Load MonitoringSina Ronaghi, Alessandro Ferrero, Simona Salicone, Harsha Vardhana Jetti. 1-6 [doi]
- Detection of Distorted Excitation Voltage of Power Transformers Using Vibration MeasurementsDennis Albert, Klaus Roppert, Andre Würde, Christoph Engelen, Robert Schürhuber, Albert Moser. 1-6 [doi]
- Revenue Metrics Ability to Correctly Register Bidirectional Active Energy Flows in Active Distribution NetworksJan Klusacek, Jiri Drapela, Roberto Langella, Jan Meyer. 1-6 [doi]
- Battery Energy Storage: An Automated System for the Simulation of Real Cycles in Domestic Renewable ApplicationsLudovica Apa, Livio D'Alvia, Zaccaria Del Prete, Emanuele Rizzuto. 1-6 [doi]
- Evaluating Varying Burden when Inductive Current Transformers are Used for Harmonic Current MeasurementsRuan Murray, Jan A. de Kock. 1-6 [doi]
- Analysis of Different Algorithms to Measure Average Active Power with Volatile FrequencyGerd Bumiller, Hans Peter Maier. 1-6 [doi]
- Synchronized Measurements for Monitoring Power Quality in DC Systems: A ProposalMichele Zanoni, Riccardo Chiumeo, Liliana Tenti, Christian Laurano, Sergio Toscani, Paolo Attilio Pegoraro. 1-6 [doi]
- Development of a Low-Cost Three-Phase Current Generator for Testing Current TransformersMarco Faifer, Christian Laurano, Roberto Ottoboni, Sergio Toscani. 1-6 [doi]
- Is Reactive Power a Zero-Quantity?Charles Trevor Gaunt, Pitambar Jankee. 1-6 [doi]
- A Reference Measurement System for Calibration of High-Voltage Transducers at Frequencies Up to 10 kHzWei Yan, Imanka Dewayalage, Ilya F. Budovsky, Frederick Emms, Yi Li. 1-6 [doi]
- Enhanced Step Location in the Magnitude and Phase of an AC Signal via Polynomial Approximation Total Variation (PATV) FilteringMarcelo Britto Martins, Paulo A. A. Esquef, Renata T. de Barros e Vasconcellos. 1-6 [doi]
- Dynamic Phasor Based Dynamic State Estimation for Converter-Driven GridsA. G. Priyanka, Sriram Karthik Gurumurthy, Antonello Monti, Ferdinanda Ponci. 1-6 [doi]
- Fault-Tolerant Implementation of the SMU with Bad-Data Detection Applied to PMU ValuesCesar Cazal, Roua Hamila, Manuel Pitz, Ferdinanda Ponci, Antonello Monti. 1-6 [doi]
- Comparison Between the Machine Learning and the Statistical Approach to the Forecasting of Voltage, Current, and FrequencyVirginia Negri, Alessandro Mingotti, Roberto Tinarelli, Lorenzo Peretto. 1-6 [doi]
- Analysis of Requirements for a Measurement Method to Assess Conducted Disturbances in the 2-500 kHz BandAlexander Gallarreta, Stefano Lodetti, Peter N. Davis, Jon González-Ramos, Igor Fernández, David de la Vega, Itziar Angulo, Amaia Arrinda. 1-6 [doi]
- Reference Measurement Systems for the Calibration of Instrument Transformers Under Power Quality Phenomena and their UncertaintiesYeying Chen, Enrico Mohns, Alessandro Mingotti, Gabriella Crotti, Palma Sara Letizia, Robert Stiegler, Hüseyin Üaye, Burak Ayhan, Fabio Muñoz. 1-6 [doi]
- Narrowband Interferers Cancellation Versus Estimation: Impact on Synchrophasor MeasurementXuansheng Shan, David Macii, He Wen, Dario Petri. 1-6 [doi]
- Fiber Optic Current Sensor Prototype for Low DC Measurements in the Power GridJohannes Mandl, Philipp Trampitsch, Philipp Schachinger, Dennis Albert, Reinhard Klambauer, Alexander Bergmann. 1-6 [doi]
- A Novel Approach to Automatically Detect Power Quality Disturbances Based on Dynamic Pocket NetworkMinjun He, Zhaosheng Teng, Alessandro Mingotti, Qiu Tang, He Wen, Lorenzo Pererto. 1-6 [doi]
- Improving the PMU StandardHarold Kirkham, Jan-Philipp Kitzig, David M. Laverty, Artis Riepnieks, Dani Strickland, D. Rod White. 1-6 [doi]
- Welcome Message from the ChairmenPaolo Attilio Pegoraro, Alessandro Mingotti, Sergio Toscani, Mario Luiso, Guglielmo Frigo. 4-15 [doi]